Creating a new diretory results in the test leaking it when it is not
removed via a defer call. All tests have already access to
`podmanTest.TempDir` which will be automatically removed in the
`AfterEach()` block.
While some test were fine other forgot the defer call. To keep the test
consitent and prevent other from making the same mistake convert all
users to `podmanTest.TempDir`. `CreateTempDirInTempDir()` is only used
for the `podmanTest.Setup()` call.
Signed-off-by: Paul Holzinger <pholzing@redhat.com>
This test was added twice once for CNI and netavark, just write it once
there is no need to do this weird skip thing.
Signed-off-by: Paul Holzinger <pholzing@redhat.com>
Allow users to customize the network_interface option is the network
config. For bridge this allows users to change the bridge name and for
maclvan it will be the same as `--opt parent=...`.
However the main reason for this option is to allow netavark plugins to
make use of it. I demoed the host-device plugin which makes use of this
as an example. While we could let users set them via --opt it is more
natural to just use the field which is designed for that purpose.
Signed-off-by: Paul Holzinger <pholzing@redhat.com>
Since commit f250560a80 the play kube command uses its own network.
this is racy be design because we create the network followed by
creating/running pod/containers. This means in the meantime another
prune or reset process could wipe out the network config because we have
to share the network config directory by design in the test.
The problem is we only have one host netns which is shared between
tests. If the network config dir is not shared we cannot make conflict
checks for interface names and ip address. This results in different
tests trying to use the same interface and/or ip address which will
cause runtime failures in CNI and netavark.
The only solution I see is to make sure only the reset/prune tests are
using a custom network dir. This makes sure they do not wipe configs
that are otherwise required by other parallel running tests.
Fixes#17946
Signed-off-by: Paul Holzinger <pholzing@redhat.com>
Unify the functions used to detect rootless to "isRootless()".
This function can detect to join the user namespace by mistake.
Signed-off-by: Toshiki Sonoda <sonoda.toshiki@fujitsu.com>
I found the ginkgolinter[1] by accident, this looks for not optimal
matching and suggest how to do it better.
Overall these fixes seem to be all correct and they will give much
better error messages when something fails.
Check out the repo to see what the linter reports.
[1] https://github.com/nunnatsa/ginkgolinter
Signed-off-by: Paul Holzinger <pholzing@redhat.com>
Since by default the network config dir is shared in the e2e tests any
other parallel running test could remove a network and cause this test to
fail.
Fixes#15990
Signed-off-by: Paul Holzinger <pholzing@redhat.com>
In view of https://github.com/containers/storage/pull/1337, do this:
for f in $(git grep -l stringid.GenerateNonCryptoID | grep -v '^vendor/'); do
sed -i 's/stringid.GenerateNonCryptoID/stringid.GenerateRandomID/g' $f;
done
Signed-off-by: Kir Kolyshkin <kolyshkin@gmail.com>
A number of standard image names were lower-case, leading to
confusion in code such as:
registry := podman(... , "-n", "registry", registry, ...)
^--- variable ^---- constant
Fix a number of those to be capitalized and with _IMAGE suffix:
registry := podman(..., REGISTRY_IMAGE
Signed-off-by: Ed Santiago <santiago@redhat.com>
add the ability to filter networks by their dangling status via:
`network ls --filter dangling=true/false`
Fixes: #14595
Signed-off-by: Carlo Lobrano <c.lobrano@gmail.com>
This is a very late followup to my ginkgo-improving work of 2021.
It has been stuck since December because it requires gomega 1.17,
which we've just enabled.
This commit is simply a copy-paste of a command I saved in
my TODO list many months ago:
sed -i -e 's/Expect(\([^ ]\+\)\.\([a-zA-Z0-9]\+\))\.To(Equal(/Expect(\1).To(HaveField(\"\2\", /' test/e2e/*_test.go
Signed-off-by: Ed Santiago <santiago@redhat.com>
This reverts commit cc3790f332.
We can't change rootful to rootfull because `rootful` is written into the machine config. Changing this will break json unmarshalling, which will break existing machines.
[NO NEW TESTS NEEDED]
Signed-off-by: Ashley Cui <acui@redhat.com>
We are inconsistent on the name, we should stick with rootfull.
[NO NEW TESTS NEEDED] Existing tests should handle this and no tests for
machines exists yet.
Signed-off-by: Daniel J Walsh <dwalsh@redhat.com>
Since this option will also be used for netavark we should rename it to
something more generic. It is important that --cni-config-dir still
works otherwise we could break existing container cleanup commands.
Signed-off-by: Paul Holzinger <pholzing@redhat.com>
The libpod/network packages were moved to c/common so that buildah can
use it as well. To prevent duplication use it in podman as well and
remove it from here.
Signed-off-by: Paul Holzinger <pholzing@redhat.com>
I noticed that this test will fail its flake rerun because the network
was not removed and it tried to create a network with the same name.
Also network disconnect works rootless now.
Signed-off-by: Paul Holzinger <pholzing@redhat.com>
Write a BeValidJSON() matcher, and replace IsJSONOutputValid():
sed -i -e 's/Expect(\(.*\)\.IsJSONOutputValid()).To(BeTrue())/Expect(\1.OutputToString())\.To(BeValidJSON())/' test/e2e/*_test.go
(Plus a few manual tweaks)
Signed-off-by: Ed Santiago <santiago@redhat.com>
Many ginkgo tests have been written to use this evil form:
GrepString("foo")
Expect(that to BeTrue())
...which yields horrible useless messages on failure:
false is not true
Identify those (automatically, via script) and convert to:
Expect(output to ContainSubstring("foo"))
...which yields:
"this output" does not contain substring "foo"
There are still many BeTrue()s left. This is just a start.
This is commit 1 of 2. It includes the script I used, and
all changes to *.go are those computed by the script.
Commit 2 will apply some manual fixes.
Signed-off-by: Ed Santiago <santiago@redhat.com>
Add --time flag to podman container rm
Add --time flag to podman pod rm
Add --time flag to podman volume rm
Add --time flag to podman network rm
Signed-off-by: Daniel J Walsh <dwalsh@redhat.com>
The podman integration tests run in parallel. Because all tests use the
same CNI config dir the podman network prune test will remove networks
which are used by other tests at the moment and thus creating
unexpected flakes.
The solution use an extra cni config dir for the network prune test.
Signed-off-by: Paul Holzinger <pholzing@redhat.com>
Make use of the new network interface in libpod.
This commit contains several breaking changes:
- podman network create only outputs the new network name and not file
path.
- podman network ls shows the network driver instead of the cni version
and plugins.
- podman network inspect outputs the new network struct and not the cni
conflist.
- The bindings and libpod api endpoints have been changed to use the new
network structure.
The container network status is stored in a new field in the state. The
status should be received with the new `c.getNetworkStatus`. This will
migrate the old status to the new format. Therefore old containers should
contine to work correctly in all cases even when network connect/
disconnect is used.
New features:
- podman network reload keeps the ip and mac for more than one network.
- podman container restore keeps the ip and mac for more than one
network.
- The network create compat endpoint can now use more than one ipam
config.
The man pages and the swagger doc are updated to reflect the latest
changes.
Signed-off-by: Paul Holzinger <pholzing@redhat.com>
e2e test failures are rife with messages like:
Expected 1 to equal 0
These make me cry. They're anti-helpful, requiring the reader
to dive into the source code to figure out what those numbers
mean.
Solution: Go tests have a '.Should(Exit(NNN))' mechanism. I
don't know if it spits out a better diagnostic (I have no way
to run e2e tests on my laptop), but I have to fantasize that
it will, and given the state of our flakes I assume that at
least one test will fail and give me the opportunity to see
what the error message looks like.
THIS IS NOT REVIEWABLE CODE. There is no way for a human
to review it. Don't bother. Maybe look at a few random
ones for sanity. If you want to really review, here is
a reproducer of what I did:
cd test/e2e
! positive assertions. The second is the same as the first,
! with the addition of (unnecessary) parentheses because
! some invocations were written that way. The third is BeZero().
perl -pi -e 's/Expect\((\S+)\.ExitCode\(\)\)\.To\(Equal\((\d+)\)\)/Expect($1).Should(Exit($2))/' *_test.go
perl -pi -e 's/Expect\((\S+)\.ExitCode\(\)\)\.To\(\(Equal\((\d+)\)\)\)/Expect($1).Should(Exit($2))/' *_test.go
perl -pi -e 's/Expect\((\S+)\.ExitCode\(\)\)\.To\(BeZero\(\)\)/Expect($1).Should(Exit(0))/' *_test.go
! Same as above, but handles three non-numeric exit codes
! in run_exit_test.go
perl -pi -e 's/Expect\((\S+)\.ExitCode\(\)\)\.To\(Equal\((\S+)\)\)/Expect($1).Should(Exit($2))/' *_test.go
! negative assertions. Difference is the spelling of 'To(Not)',
! 'ToNot', and 'NotTo'. I assume those are all the same.
perl -pi -e 's/Expect\((\S+)\.ExitCode\(\)\)\.To\(Not\(Equal\((0)\)\)\)/Expect($1).To(ExitWithError())/' *_test.go
perl -pi -e 's/Expect\((\S+)\.ExitCode\(\)\)\.ToNot\(Equal\((0)\)\)/Expect($1).To(ExitWithError())/' *_test.go
perl -pi -e 's/Expect\((\S+)\.ExitCode\(\)\)\.NotTo\(Equal\((0)\)\)/Expect($1).To(ExitWithError())/' *_test.go
! negative, old use of BeZero()
perl -pi -e 's/Expect\((\S+)\.ExitCode\(\)\)\.ToNot\(BeZero\(\)\)/Expect($1).Should(ExitWithError())/' *_test.go
Run those on a clean copy of main branch (at the same branch
point as my PR, of course), then diff against a checked-out
copy of my PR. There should be no differences. Then all you
have to review is that my replacements above are sane.
UPDATE: nope, that's not enough, you also need to add gomega/gexec
to the files that don't have it:
perl -pi -e '$_ .= "$1/gexec\"\n" if m!^(.*/onsi/gomega)"!' $(grep -L gomega/gexec $(git log -1 --stat | awk '$1 ~ /test\/e2e\// { print $1}'))
UPDATE 2: hand-edit run_volume_test.go
UPDATE 3: sigh, add WaitWithDefaultTimeout() to a couple of places
UPDATE 4: skip a test due to bug #10935 (race condition)
Signed-off-by: Ed Santiago <santiago@redhat.com>
Creating a macvlan network with the subnet or ipRange option should set
the ipam plugin type to `host-local`. We also have to insert the default
route.
Fixes#10283
Signed-off-by: Paul Holzinger <paul.holzinger@web.de>
Added ID to default
removed outdated imports
slight refactor
Test Network Headers added to network_test.go
Signed-off-by: Parker Van Roy <pvanroy@redhat.com>
We missed bumping the go module, so let's do it now :)
* Automated go code with github.com/sirkon/go-imports-rename
* Manually via `vgrep podman/v2` the rest
Signed-off-by: Valentin Rothberg <rothberg@redhat.com>
The logic in the e2e test for multiple network aliases is indicating the
test should wait for the containerized nginx to be ready. As this may
take some time, the test does an exponential backoff starting at 2050ms.
Fix the logic by removing the `Expect(...)` call during the exponential
backoff. Otherwise, the test errors immediately.
Signed-off-by: Valentin Rothberg <rothberg@redhat.com>
add the ability to prune unused cni networks. filters are not implemented
but included both compat and podman api endpoints.
Fixes :#8673
Signed-off-by: baude <bbaude@redhat.com>
when creating a macvlan network, we should honor gateway, subnet, and
mtu as provided by the user.
Fixes: #9167
Signed-off-by: baude <bbaude@redhat.com>
instead of using the --macvlan to indicate that you want to make a
macvlan network, podman network create now honors the driver name of
*macvlan*. Any options to macvlan, like the parent device, should be
specified as a -o option. For example, -o parent=eth0.
the --macvlan option was marked as deprecated in the man page but is
still supported for the duration of 3.0.
Signed-off-by: baude <bbaude@redhat.com>
Make sure we pass the network aliases as capability args to the
cnitool in the rootless-cni-infra container. Also update the
dnsname plugin in the cni-infra container.
Fixes#8567
Signed-off-by: Paul Holzinger <paul.holzinger@web.de>
Unlike the container storage all e2e test are using the same cni
config directory. This causes problems if the network name already
exists. Using random names will make the second run pass even if the
first failed. This is only done to prevent full CI failures.
Signed-off-by: Paul Holzinger <paul.holzinger@web.de>
The network ID is not stored. It is just the sha256 hash from
the network name. There is a risk of a potential hash collision.
However it's very unlikely and even if we hit this it will
complain that more than network with this ID exists.
The main benefit is that the compat api can have proper
network ID support. Also this adds the support for
`podman network ls --format "{{.ID}}"` and `--filter id=<ID>`.
It also ensures that we can do network rm <ID> and network
inspect <ID>.
Since we use a hash this commit is backwards compatible even for
already existing networks.
Signed-off-by: Paul Holzinger <paul.holzinger@web.de>
Add label support for podman network create. Use the `args`
field in the cni config file to store the podman labels.
Use `podman_labels` as key name and store the labels as
map[string]string.
For reference: https://github.com/containernetworking/cni/blob/master/CONVENTIONS.md#args-in-network-confighttps://github.com/containernetworking/cni/blob/spec-v0.4.0/SPEC.md#network-configuration
Example snippet:
```
...
"args": {
"podman_labels": {
"key1":"value1",
"key2":"value2"
}
}
...
```
Make podman network list support several filters. Supported filters are name,
plugin, driver and label. Filters with different keys work exclusive. Several label
filters work exclusive and the other filter keys are working inclusive.
Also adjust the compat api to support labels in network create and list.
Breaking changes:
- podman network ls -f shortform is used for --filter instead --format
This matches docker and other podman commands (container ps, volume ps)
- libpod network list endpoint filter parameter is removed. Instead the
filters paramter should be used as json encoded map[string][]string.
Signed-off-by: Paul Holzinger <paul.holzinger@web.de>