Continuous profiler
[!IMPORTANT]
Continuous profiler is an experimental feature. It will be subject to change, when https://github.com/open-telemetry/oteps/pull/239 or https://github.com/open-telemetry/oteps/pull/237 are merged.
The continuous profiler collects stack traces from the processes for two type of events:
- Periodically, for all threads. See Thread sampling.
- Memory allocation events. See Allocation sampling.
You can export stack traces to any observability back end that supports profiling.
Thread sampling
You can enable thread sampling using the custom plugin, which can parse dense thread sampling data and export it.
How does the thread sampler work?
The profiler uses the .NET profiler to perform periodic call stack sampling. For every sampling period, the runtime suspends execution and the samples for all managed thread are saved in the buffer, then the runtime resumes.
The separate managed thread processes data from the buffer and exports it in the format defined by the plugin. To make the process more efficient, the sampler uses two independent buffers to store samples alternatively.
Requirements
- .NET 6.0 or higher (
ICorProfilerInfo12
available in runtime). - .NET Framework is not supported, as
ICorProfiler10
andICorProfiler12
are not available in .NET Fx.
Note that ICorProfiler10
can be used, but .NET Core 3.1 or .NET 5.0 aren't
supported by the OpenTelemetry .NET Automatic Instrumentation.
Enable the profiler
Implement custom plugin. See plugin section.
Configuration defaults
threadSamplingEnabled = true;
: Enables thread sampling.var threadSamplingInterval = 10000u;
: Sampling interval, in milliseconds. Lowest recommended value is 1000.var exportInterval = TimeSpan.FromMilliseconds(500);
: Interval for reading the data from buffers and call the exporter. This setting is common for both thread and allocation sampling.object continuousProfilerExporter = new ConsoleExporter();
: Exporter to be used for both thread and allocation sampling.
Escape hatch
The profiler limits its own behavior when both buffers used to store sampled data are full.
This scenario might happen when the data processing thread is not able to export data the given period of time.
Thread sampling resumes when any of the buffers are empty.
Troubleshoot the .NET profiler
How do I know if it's working?
At startup, the OpenTelemetry Instrumentation for .NET logs the string
ContinuousProfiler::StartThreadSampling
at info
log level.
You can grep for this in the native logs for the instrumentation to see something like this:
10/12/22 12:10:31.962 PM [12096|22036] [info] ContinuousProfiler::StartThreadSampling
How can I see Continuous Profiling configuration?
The OpenTelemetry .NET Automatic Instrumentation logs the profiling configuration
at Debug
log level during the startup. You can grep for the string
Continuous profiling configuration:
to see the configuration.
What does the escape hatch do?
The escape hatch automatically discards profiling data if the ingest limit has been reached.
If the escape hatch activates, it logs the following message:
Skipping a thread sample period, buffers are full.
You can also look for:
** THIS WILL RESULT IN LOSS OF PROFILING DATA **.
If you see these log messages, check the exporter implementation.
What if I'm on an unsupported .NET version?
None of the .NET Framework versions is supported. You have to switch to a supported .NET version.
Can I tell the sampler to ignore some threads?
There is no such functionality. All managed threads are captured by the profiler.
Allocation sampling
The profiler samples allocations, captures the call stack state for the .NET thread that triggered the allocation, and exports it in the appropriate format.
Use the memory allocation data, together with the stack traces and .NET runtime metrics, to investigate memory leaks and unusual consumption patterns in an observability back end that supports profiling.
How does the memory profiler work?
The profiler leverages .NET profiling to perform allocation sampling. For every sampled allocation, allocation amount together with stack trace of the thread that triggered the allocation, and associated span context, are saved into buffer.
The managed thread shared with CPU Profiler processes the data from the buffer and exports in the way defined by the plugin..
Requirements
- .NET 6.0 or higher (
ICorProfilerInfo12
available in runtime) - technically it could be .NET5 which is not supported by OTel/MS.
Enable the profiler
Implement custom plugin.
Configuration settings by the plugin
threadSamplingEnabled, threadSamplingInterval, allocationSamplingEnabled, maxMemorySamplesPerMinute, exportInterval, continuousProfilerExporter
allocationSamplingEnabled = true
maxMemorySamplesPerMinute = 200
// minimum value: 1, Splunk is using 200 by defaultexportInterval = TimeSpan.FromMilliseconds(500);
// Interval to read data from buffers and call exporter, common for Thread and Allocation samplingobject continuousProfilerExporter = new ConsoleExporter();
// Exporter, common for Thread and Allocation sampling
Escape hatch
The profiler limits its own behavior when buffer used to store allocation samples is full.
Current maximum size of the buffer is 200 KiB.
This scenario might happen when the data processing thread is not able to export the data by the plugin in the given time frame.
Troubleshooting the .NET profiler
How do I know if it's working?
At the startup, the OpenTelemetry .NET Automatic Instrumentation will log the string
ContinuousProfiler::MemoryProfiling started
at info
log level.
You can grep for this in the native logs for the instrumentation to see something like this:
10/12/23 12:10:31.962 PM [12096|22036] [info] ContinuousProfiler::MemoryProfiling started.
How can I see Continuous Profiling configuration?
The OpenTelemetry .NET AutomaticInstrumentation logs the profiling configuration
at Debug
log level during the startup. You can grep for the string
Continuous profiling configuration:
to see the configuration.
What does the escape hatch do?
The escape hatch automatically discards captured allocation data if the ingest limit has been reached.
If the escape hatch activates, it logs the following message:
Discarding captured allocation sample. Allocation buffer is full.
If you see these log messages, check the configuration and communication layer between your process and the Collector.
What if I'm on an unsupported .NET version?
None of the .NET Framework versions is supported. You have to switch to supported .NET version.
Plugin
For now, the plugins is responsible for
- defining configuration for continuous profiling
- providing exporter for the allocation and profiling data
- parsing data prepared by the native code.
Plugin contract
[!IMPORTANT]
It will be subject to change, when https://github.com/open-telemetry/oteps/pull/239 or https://github.com/open-telemetry/oteps/pull/237 will be ready and merged.
As other methods, GetContinuousProfilerConfiguration
is called by reflection
and convention.
/// <summary>
/// Configure Continuous Profiler.
/// </summary>
/// <returns>(threadSamplingEnabled, threadSamplingInterval, allocationSamplingEnabled, maxMemorySamplesPerMinute, exportInterval, exportTimeout, continuousProfilerExporter)</returns>
public Tuple<bool, uint, bool, uint, TimeSpan, TimeSpan, object> GetContinuousProfilerConfiguration()
{
var threadSamplingEnabled = true; // enables thread sampling
var threadSamplingInterval = 10000u; // interval to stop CLR runtime and fetch stacks. 10 000ms is Splunk default. 1000ms is the lowest supported value by Splunk. The code does not contains any limitations this. Plugins is responsible for checks.
var allocationSamplingEnabled = true; // enables allocation sampling
var maxMemorySamplesPerMinute = 200u; // max number of samples in minutes. 200 is tested default value by Splunk.
var exportInterval = TimeSpan.FromMilliseconds(500); // Pause time before next execution of exporting/reading buffer process
var exportTimeout = TimeSpan.FromMilliseconds(500); // Export timeout
object continuousProfilerExporter = new ConsoleExporter();
return Tuple.Create(threadSamplingEnabled, threadSamplingInterval, allocationSamplingEnabled, maxMemorySamplesPerMinute, exportInterval, exportTimeout, continuousProfilerExporter);
}
if more than one plugin implement GetContinuousProfilerConfiguration
only
the first one will be used. Other will be ignored.
Exporter contract
Two methods has to be implemented by Exporter
public void ExportThreadSamples(byte[] buffer, int read, CancellationToken cancellationToken);
public void ExportAllocationSamples(byte[] buffer, int read, CancellationToken cancellationToken);
Both accept buffer produced by the native code, the length of filled data, and cancellation token. The Exporter is responsible both for parsing this buffer and exporting it.
Example: OtlpOverHttpExporter
.
Native parser
As there is no default OpenTelemetry Protocol format there is not easy way to create good contract between OpenTelemetry Automatic Instrumentation and the plugin. The plugin has to implement (copy) our version of the parser. It should be changed when the OTel Proposal will be merged, and we can start implementing real OTLP exporter.
Implementation can be found in SampleNativeFormatParser
.