# Metric Requirement Levels
**Status**: [Stable][DocumentStatus]
<details>
<summary>Table of Contents</summary>
<!-- toc -->
- [Required](#required)
- [Recommended](#recommended)
- [Opt-In](#opt-in)
<!-- tocstop -->
</details>
The following metric requirement levels are specified:
- [Required](#required)
- [Recommended](#recommended)
- [Opt-In](#opt-in)
## Required
All instrumentations MUST emit the metric.
A semantic convention defining a Required metric expects that an absolute majority of instrumentation libraries and applications are able to efficiently emit it.
## Recommended
Instrumentations SHOULD emit the metric by default if it's readily available and can be efficiently emitted. Instrumentations MAY offer a configuration option to disable Recommended metrics.
Instrumentations that decide not to emit `Recommended` metrics due to performance, security, privacy, or other consideration by default, SHOULD allow for opting in to emitting them as defined for the `Opt-In` requirement level if the metrics are logically applicable.
## Opt-In
Instrumentations SHOULD emit the metric if and only if the user configures the instrumentation to do so.
Instrumentation that doesn't support configuration MUST NOT emit `Opt-In` metrics.
This attribute requirement level is recommended for metrics that are particularly expensive to retrieve or might pose a security or privacy risk. These should therefore only be enabled deliberately by a user making an informed decision.